SheerWeave 7000 - Sun Control

SheerWeave 7000

Style 7000 is uniquely designed to provide total light blockage when complete room darkening is needed. With a broad range of decorator colors, the look and feel of rich cloth and a PVC-free composition, Style 7000 will enhance the beauty and function of both commercial and residential spaces.

 

Railroading this fabric is not recommended. Colors may vary slightly from swatch samples. All variations are within industry standards. 

 

Photo above courtesy of Lafayette Venetian Blind

SheerWeave 7000

Click on the swatches below to view all fabric specifications, color range and other details including technical data, solar optical properties and shading coefficients.

More Information

Print

ShareIt

GreenGuard

SheerWeave Style 7000
P62 White

Style 7000 is uniquely designed to provide total light blockage when complete room darkening is needed. With a broad range of decorator colors, the look and feel of rich cloth and a PVC-free composition, Style 7000 will enhance the beauty and function of both commercial and residential spaces.

Specifications
Fire Classification
California U.S. Title 19 (small scale), NFPA 701-2004 TM#1 (small scale), BS 5867 2008 Part 2 Type B Performance, CAN/ULC-S 109-03 (large and small scale), ASTM E 84 (Class 1), and CAN/CGSB2-4.162-M80
Bacteria and Fungal Resistance
ASTM G21-96, AATCC 174-1998 Part II and III
Environmental Certification
Certified to GREENGUARD and GREENGUARD Gold standards for low chemical emissions into indoor air during product usage
Lead Free
RoHS/Directive 2002/95/EC, US Consumer Product Safety Commission Section 101 and ANSI/WCMA A 100.1-2007 for lead content
Standard Uses
Roll-up shade
Warranty
5-year interior

Technical Data

Standard Widths 94" and 118" (238.8cm and 299.7cm)
Standard Roll Length 30 Linear yards (27.4m)
Composition 100% Polyester with Acrylic Foamed Backing (PVC-free)
Mesh Weight 13.41 oz/yd2 (454.67 g/m2)
Fabric Thickness .026 in (0.66mm)
Openness Factor Opaque
Acoustical Value NRC 0.10 / SAA 0.08
Acoustical Performance NRC (Noise Reduction Coefficient) and SAA (Sound Absorption Average) tested in accordance with ASTM C423-09a.
SheerWeave Style 7000 Solar Optical Properties SHGC/G Value g-tot (glass & blind)
Single Insulating
Solar
Transmittance
Solar
Reflectance
Solar
Absorption
Visual
Transmittance
1/8CL 1/4CL 1/4HA 1CL 1HA
7000 P62 White 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 P64 Sand 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 P63 Birch 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 Q57 Wheat 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 Q58 Mushroom 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 U67 Canvas 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 U69 Cocoa 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 V41 Canyon 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 V39 Graphite 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 V40 Onyx 0 64 36 0 0.27 0.27 0.26 0.26 0.21

*TS - Solar Transmittance, RS - Solar Reflectance, AS - Solar Absorption, TV - Visual Transmittance *SHGC = Solar Heat Gain Coefficient *1/4 CL = 1/4" Clear Glass, 1 HA = 1" Heat Absorbing Glass *Fabrics Installed Internally, Zero-Degree Profile Angle *Solar Heat Gain Coefficient (SHGC) shown calculated according to Office of Building Technology, State and Community Programs, Energy Efficiency and Renewable Energy, U.S. Department of Energy’s definition of SHGC. SHGC represents the percentage of solar heat gain that is transmitted to the interior through the glass and shading system. If you are using glass whose performance is listed in terms of SC, you may convert to SHGC by multiplying the SC by 0.87.

More Information

Print

ShareIt

GreenGuard

SheerWeave Style 7000
P64 Sand

Style 7000 is uniquely designed to provide total light blockage when complete room darkening is needed. With a broad range of decorator colors, the look and feel of rich cloth and a PVC-free composition, Style 7000 will enhance the beauty and function of both commercial and residential spaces.

Specifications
Fire Classification
California U.S. Title 19 (small scale), NFPA 701-2004 TM#1 (small scale), BS 5867 2008 Part 2 Type B Performance, CAN/ULC-S 109-03 (large and small scale), ASTM E 84 (Class 1), and CAN/CGSB2-4.162-M80
Bacteria and Fungal Resistance
ASTM G21-96, AATCC 174-1998 Part II and III
Environmental Certification
Certified to GREENGUARD and GREENGUARD Gold standards for low chemical emissions into indoor air during product usage
Lead Free
RoHS/Directive 2002/95/EC, US Consumer Product Safety Commission Section 101 and ANSI/WCMA A 100.1-2007 for lead content
Standard Uses
Roll-up shade
Warranty
5-year interior

Technical Data

Standard Widths 94" and 118" (238.8cm and 299.7cm)
Standard Roll Length 30 Linear yards (27.4m)
Composition 100% Polyester with Acrylic Foamed Backing (PVC-free)
Mesh Weight 13.41 oz/yd2 (454.67 g/m2)
Fabric Thickness .026 in (0.66mm)
Openness Factor Opaque
Acoustical Value NRC 0.10 / SAA 0.08
Acoustical Performance NRC (Noise Reduction Coefficient) and SAA (Sound Absorption Average) tested in accordance with ASTM C423-09a.
SheerWeave Style 7000 Solar Optical Properties SHGC/G Value g-tot (glass & blind)
Single Insulating
Solar
Transmittance
Solar
Reflectance
Solar
Absorption
Visual
Transmittance
1/8CL 1/4CL 1/4HA 1CL 1HA
7000 P62 White 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 P64 Sand 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 P63 Birch 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 Q57 Wheat 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 Q58 Mushroom 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 U67 Canvas 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 U69 Cocoa 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 V41 Canyon 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 V39 Graphite 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 V40 Onyx 0 64 36 0 0.27 0.27 0.26 0.26 0.21

*TS - Solar Transmittance, RS - Solar Reflectance, AS - Solar Absorption, TV - Visual Transmittance *SHGC = Solar Heat Gain Coefficient *1/4 CL = 1/4" Clear Glass, 1 HA = 1" Heat Absorbing Glass *Fabrics Installed Internally, Zero-Degree Profile Angle *Solar Heat Gain Coefficient (SHGC) shown calculated according to Office of Building Technology, State and Community Programs, Energy Efficiency and Renewable Energy, U.S. Department of Energy’s definition of SHGC. SHGC represents the percentage of solar heat gain that is transmitted to the interior through the glass and shading system. If you are using glass whose performance is listed in terms of SC, you may convert to SHGC by multiplying the SC by 0.87.

More Information

Print

ShareIt

GreenGuard

SheerWeave Style 7000
P63 Birch

Style 7000 is uniquely designed to provide total light blockage when complete room darkening is needed. With a broad range of decorator colors, the look and feel of rich cloth and a PVC-free composition, Style 7000 will enhance the beauty and function of both commercial and residential spaces.

Specifications
Fire Classification
California U.S. Title 19 (small scale), NFPA 701-2004 TM#1 (small scale), BS 5867 2008 Part 2 Type B Performance, CAN/ULC-S 109-03 (large and small scale), ASTM E 84 (Class 1), and CAN/CGSB2-4.162-M80
Bacteria and Fungal Resistance
ASTM G21-96, AATCC 174-1998 Part II and III
Environmental Certification
Certified to GREENGUARD and GREENGUARD Gold standards for low chemical emissions into indoor air during product usage
Lead Free
RoHS/Directive 2002/95/EC, US Consumer Product Safety Commission Section 101 and ANSI/WCMA A 100.1-2007 for lead content
Standard Uses
Roll-up shade
Warranty
5-year interior

Technical Data

Standard Widths 94" and 118" (238.8cm and 299.7cm)
Standard Roll Length 30 Linear yards (27.4m)
Composition 100% Polyester with Acrylic Foamed Backing (PVC-free)
Mesh Weight 13.41 oz/yd2 (454.67 g/m2)
Fabric Thickness .026 in (0.66mm)
Openness Factor Opaque
Acoustical Value NRC 0.10 / SAA 0.08
Acoustical Performance NRC (Noise Reduction Coefficient) and SAA (Sound Absorption Average) tested in accordance with ASTM C423-09a.
SheerWeave Style 7000 Solar Optical Properties SHGC/G Value g-tot (glass & blind)
Single Insulating
Solar
Transmittance
Solar
Reflectance
Solar
Absorption
Visual
Transmittance
1/8CL 1/4CL 1/4HA 1CL 1HA
7000 P62 White 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 P64 Sand 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 P63 Birch 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 Q57 Wheat 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 Q58 Mushroom 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 U67 Canvas 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 U69 Cocoa 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 V41 Canyon 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 V39 Graphite 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 V40 Onyx 0 64 36 0 0.27 0.27 0.26 0.26 0.21

*TS - Solar Transmittance, RS - Solar Reflectance, AS - Solar Absorption, TV - Visual Transmittance *SHGC = Solar Heat Gain Coefficient *1/4 CL = 1/4" Clear Glass, 1 HA = 1" Heat Absorbing Glass *Fabrics Installed Internally, Zero-Degree Profile Angle *Solar Heat Gain Coefficient (SHGC) shown calculated according to Office of Building Technology, State and Community Programs, Energy Efficiency and Renewable Energy, U.S. Department of Energy’s definition of SHGC. SHGC represents the percentage of solar heat gain that is transmitted to the interior through the glass and shading system. If you are using glass whose performance is listed in terms of SC, you may convert to SHGC by multiplying the SC by 0.87.

More Information

Print

ShareIt

GreenGuard

SheerWeave Style 7000
Q57 Wheat

Style 7000 is uniquely designed to provide total light blockage when complete room darkening is needed. With a broad range of decorator colors, the look and feel of rich cloth and a PVC-free composition, Style 7000 will enhance the beauty and function of both commercial and residential spaces.

Specifications
Fire Classification
California U.S. Title 19 (small scale), NFPA 701-2004 TM#1 (small scale), BS 5867 2008 Part 2 Type B Performance, CAN/ULC-S 109-03 (large and small scale), ASTM E 84 (Class 1), and CAN/CGSB2-4.162-M80
Bacteria and Fungal Resistance
ASTM G21-96, AATCC 174-1998 Part II and III
Environmental Certification
Certified to GREENGUARD and GREENGUARD Gold standards for low chemical emissions into indoor air during product usage
Lead Free
RoHS/Directive 2002/95/EC, US Consumer Product Safety Commission Section 101 and ANSI/WCMA A 100.1-2007 for lead content
Standard Uses
Roll-up shade
Warranty
5-year interior

Technical Data

Standard Widths 94" and 118" (238.8cm and 299.7cm)
Standard Roll Length 30 Linear yards (27.4m)
Composition 100% Polyester with Acrylic Foamed Backing (PVC-free)
Mesh Weight 13.41 oz/yd2 (454.67 g/m2)
Fabric Thickness .026 in (0.66mm)
Openness Factor Opaque
Acoustical Value NRC 0.10 / SAA 0.08
Acoustical Performance NRC (Noise Reduction Coefficient) and SAA (Sound Absorption Average) tested in accordance with ASTM C423-09a.
SheerWeave Style 7000 Solar Optical Properties SHGC/G Value g-tot (glass & blind)
Single Insulating
Solar
Transmittance
Solar
Reflectance
Solar
Absorption
Visual
Transmittance
1/8CL 1/4CL 1/4HA 1CL 1HA
7000 P62 White 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 P64 Sand 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 P63 Birch 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 Q57 Wheat 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 Q58 Mushroom 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 U67 Canvas 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 U69 Cocoa 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 V41 Canyon 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 V39 Graphite 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 V40 Onyx 0 64 36 0 0.27 0.27 0.26 0.26 0.21

*TS - Solar Transmittance, RS - Solar Reflectance, AS - Solar Absorption, TV - Visual Transmittance *SHGC = Solar Heat Gain Coefficient *1/4 CL = 1/4" Clear Glass, 1 HA = 1" Heat Absorbing Glass *Fabrics Installed Internally, Zero-Degree Profile Angle *Solar Heat Gain Coefficient (SHGC) shown calculated according to Office of Building Technology, State and Community Programs, Energy Efficiency and Renewable Energy, U.S. Department of Energy’s definition of SHGC. SHGC represents the percentage of solar heat gain that is transmitted to the interior through the glass and shading system. If you are using glass whose performance is listed in terms of SC, you may convert to SHGC by multiplying the SC by 0.87.

More Information

Print

ShareIt

GreenGuard

SheerWeave Style 7000
Q58 Mushroom

Style 7000 is uniquely designed to provide total light blockage when complete room darkening is needed. With a broad range of decorator colors, the look and feel of rich cloth and a PVC-free composition, Style 7000 will enhance the beauty and function of both commercial and residential spaces.

Specifications
Fire Classification
California U.S. Title 19 (small scale), NFPA 701-2004 TM#1 (small scale), BS 5867 2008 Part 2 Type B Performance, CAN/ULC-S 109-03 (large and small scale), ASTM E 84 (Class 1), and CAN/CGSB2-4.162-M80
Bacteria and Fungal Resistance
ASTM G21-96, AATCC 174-1998 Part II and III
Environmental Certification
Certified to GREENGUARD and GREENGUARD Gold standards for low chemical emissions into indoor air during product usage
Lead Free
RoHS/Directive 2002/95/EC, US Consumer Product Safety Commission Section 101 and ANSI/WCMA A 100.1-2007 for lead content
Standard Uses
Roll-up shade
Warranty
5-year interior

Technical Data

Standard Widths 94" and 118" (238.8cm and 299.7cm)
Standard Roll Length 30 Linear yards (27.4m)
Composition 100% Polyester with Acrylic Foamed Backing (PVC-free)
Mesh Weight 13.41 oz/yd2 (454.67 g/m2)
Fabric Thickness .026 in (0.66mm)
Openness Factor Opaque
Acoustical Value NRC 0.10 / SAA 0.08
Acoustical Performance NRC (Noise Reduction Coefficient) and SAA (Sound Absorption Average) tested in accordance with ASTM C423-09a.
SheerWeave Style 7000 Solar Optical Properties SHGC/G Value g-tot (glass & blind)
Single Insulating
Solar
Transmittance
Solar
Reflectance
Solar
Absorption
Visual
Transmittance
1/8CL 1/4CL 1/4HA 1CL 1HA
7000 P62 White 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 P64 Sand 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 P63 Birch 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 Q57 Wheat 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 Q58 Mushroom 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 U67 Canvas 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 U69 Cocoa 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 V41 Canyon 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 V39 Graphite 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 V40 Onyx 0 64 36 0 0.27 0.27 0.26 0.26 0.21

*TS - Solar Transmittance, RS - Solar Reflectance, AS - Solar Absorption, TV - Visual Transmittance *SHGC = Solar Heat Gain Coefficient *1/4 CL = 1/4" Clear Glass, 1 HA = 1" Heat Absorbing Glass *Fabrics Installed Internally, Zero-Degree Profile Angle *Solar Heat Gain Coefficient (SHGC) shown calculated according to Office of Building Technology, State and Community Programs, Energy Efficiency and Renewable Energy, U.S. Department of Energy’s definition of SHGC. SHGC represents the percentage of solar heat gain that is transmitted to the interior through the glass and shading system. If you are using glass whose performance is listed in terms of SC, you may convert to SHGC by multiplying the SC by 0.87.

More Information

Print

ShareIt

GreenGuard

SheerWeave Style 7000
U67 Canvas

Style 7000 is uniquely designed to provide total light blockage when complete room darkening is needed. With a broad range of decorator colors, the look and feel of rich cloth and a PVC-free composition, Style 7000 will enhance the beauty and function of both commercial and residential spaces.

Specifications
Fire Classification
California U.S. Title 19 (small scale), NFPA 701-2004 TM#1 (small scale), BS 5867 2008 Part 2 Type B Performance, CAN/ULC-S 109-03 (large and small scale), ASTM E 84 (Class 1), and CAN/CGSB2-4.162-M80
Bacteria and Fungal Resistance
ASTM G21-96, AATCC 174-1998 Part II and III
Environmental Certification
Certified to GREENGUARD and GREENGUARD Gold standards for low chemical emissions into indoor air during product usage
Lead Free
RoHS/Directive 2002/95/EC, US Consumer Product Safety Commission Section 101 and ANSI/WCMA A 100.1-2007 for lead content
Standard Uses
Roll-up shade
Warranty
5-year interior

Technical Data

Standard Widths 94" and 118" (238.8cm and 299.7cm)
Standard Roll Length 30 Linear yards (27.4m)
Composition 100% Polyester with Acrylic Foamed Backing (PVC-free)
Mesh Weight 13.41 oz/yd2 (454.67 g/m2)
Fabric Thickness .026 in (0.66mm)
Openness Factor Opaque
Acoustical Value NRC 0.10 / SAA 0.08
Acoustical Performance NRC (Noise Reduction Coefficient) and SAA (Sound Absorption Average) tested in accordance with ASTM C423-09a.
SheerWeave Style 7000 Solar Optical Properties SHGC/G Value g-tot (glass & blind)
Single Insulating
Solar
Transmittance
Solar
Reflectance
Solar
Absorption
Visual
Transmittance
1/8CL 1/4CL 1/4HA 1CL 1HA
7000 P62 White 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 P64 Sand 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 P63 Birch 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 Q57 Wheat 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 Q58 Mushroom 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 U67 Canvas 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 U69 Cocoa 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 V41 Canyon 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 V39 Graphite 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 V40 Onyx 0 64 36 0 0.27 0.27 0.26 0.26 0.21

*TS - Solar Transmittance, RS - Solar Reflectance, AS - Solar Absorption, TV - Visual Transmittance *SHGC = Solar Heat Gain Coefficient *1/4 CL = 1/4" Clear Glass, 1 HA = 1" Heat Absorbing Glass *Fabrics Installed Internally, Zero-Degree Profile Angle *Solar Heat Gain Coefficient (SHGC) shown calculated according to Office of Building Technology, State and Community Programs, Energy Efficiency and Renewable Energy, U.S. Department of Energy’s definition of SHGC. SHGC represents the percentage of solar heat gain that is transmitted to the interior through the glass and shading system. If you are using glass whose performance is listed in terms of SC, you may convert to SHGC by multiplying the SC by 0.87.

More Information

Print

ShareIt

GreenGuard

SheerWeave Style 7000
U69 Cocoa

Style 7000 is uniquely designed to provide total light blockage when complete room darkening is needed. With a broad range of decorator colors, the look and feel of rich cloth and a PVC-free composition, Style 7000 will enhance the beauty and function of both commercial and residential spaces.

Specifications
Fire Classification
California U.S. Title 19 (small scale), NFPA 701-2004 TM#1 (small scale), BS 5867 2008 Part 2 Type B Performance, CAN/ULC-S 109-03 (large and small scale), ASTM E 84 (Class 1), and CAN/CGSB2-4.162-M80
Bacteria and Fungal Resistance
ASTM G21-96, AATCC 174-1998 Part II and III
Environmental Certification
Certified to GREENGUARD and GREENGUARD Gold standards for low chemical emissions into indoor air during product usage
Lead Free
RoHS/Directive 2002/95/EC, US Consumer Product Safety Commission Section 101 and ANSI/WCMA A 100.1-2007 for lead content
Standard Uses
Roll-up shade
Warranty
5-year interior

Technical Data

Standard Widths 94" and 118" (238.8cm and 299.7cm)
Standard Roll Length 30 Linear yards (27.4m)
Composition 100% Polyester with Acrylic Foamed Backing (PVC-free)
Mesh Weight 13.41 oz/yd2 (454.67 g/m2)
Fabric Thickness .026 in (0.66mm)
Openness Factor Opaque
Acoustical Value NRC 0.10 / SAA 0.08
Acoustical Performance NRC (Noise Reduction Coefficient) and SAA (Sound Absorption Average) tested in accordance with ASTM C423-09a.
SheerWeave Style 7000 Solar Optical Properties SHGC/G Value g-tot (glass & blind)
Single Insulating
Solar
Transmittance
Solar
Reflectance
Solar
Absorption
Visual
Transmittance
1/8CL 1/4CL 1/4HA 1CL 1HA
7000 P62 White 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 P64 Sand 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 P63 Birch 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 Q57 Wheat 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 Q58 Mushroom 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 U67 Canvas 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 U69 Cocoa 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 V41 Canyon 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 V39 Graphite 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 V40 Onyx 0 64 36 0 0.27 0.27 0.26 0.26 0.21

*TS - Solar Transmittance, RS - Solar Reflectance, AS - Solar Absorption, TV - Visual Transmittance *SHGC = Solar Heat Gain Coefficient *1/4 CL = 1/4" Clear Glass, 1 HA = 1" Heat Absorbing Glass *Fabrics Installed Internally, Zero-Degree Profile Angle *Solar Heat Gain Coefficient (SHGC) shown calculated according to Office of Building Technology, State and Community Programs, Energy Efficiency and Renewable Energy, U.S. Department of Energy’s definition of SHGC. SHGC represents the percentage of solar heat gain that is transmitted to the interior through the glass and shading system. If you are using glass whose performance is listed in terms of SC, you may convert to SHGC by multiplying the SC by 0.87.

More Information

Print

ShareIt

GreenGuard

SheerWeave Style 7000
V41 Canyon

Style 7000 is uniquely designed to provide total light blockage when complete room darkening is needed. With a broad range of decorator colors, the look and feel of rich cloth and a PVC-free composition, Style 7000 will enhance the beauty and function of both commercial and residential spaces.

Specifications
Fire Classification
California U.S. Title 19 (small scale), NFPA 701-2004 TM#1 (small scale), BS 5867 2008 Part 2 Type B Performance, CAN/ULC-S 109-03 (large and small scale), ASTM E 84 (Class 1), and CAN/CGSB2-4.162-M80
Bacteria and Fungal Resistance
ASTM G21-96, AATCC 174-1998 Part II and III
Environmental Certification
Certified to GREENGUARD and GREENGUARD Gold standards for low chemical emissions into indoor air during product usage
Lead Free
RoHS/Directive 2002/95/EC, US Consumer Product Safety Commission Section 101 and ANSI/WCMA A 100.1-2007 for lead content
Standard Uses
Roll-up shade
Warranty
5-year interior

Technical Data

Standard Widths 94" and 118" (238.8cm and 299.7cm)
Standard Roll Length 30 Linear yards (27.4m)
Composition 100% Polyester with Acrylic Foamed Backing (PVC-free)
Mesh Weight 13.41 oz/yd2 (454.67 g/m2)
Fabric Thickness .026 in (0.66mm)
Openness Factor Opaque
Acoustical Value NRC 0.10 / SAA 0.08
Acoustical Performance NRC (Noise Reduction Coefficient) and SAA (Sound Absorption Average) tested in accordance with ASTM C423-09a.
SheerWeave Style 7000 Solar Optical Properties SHGC/G Value g-tot (glass & blind)
Single Insulating
Solar
Transmittance
Solar
Reflectance
Solar
Absorption
Visual
Transmittance
1/8CL 1/4CL 1/4HA 1CL 1HA
7000 P62 White 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 P64 Sand 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 P63 Birch 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 Q57 Wheat 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 Q58 Mushroom 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 U67 Canvas 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 U69 Cocoa 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 V41 Canyon 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 V39 Graphite 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 V40 Onyx 0 64 36 0 0.27 0.27 0.26 0.26 0.21

*TS - Solar Transmittance, RS - Solar Reflectance, AS - Solar Absorption, TV - Visual Transmittance *SHGC = Solar Heat Gain Coefficient *1/4 CL = 1/4" Clear Glass, 1 HA = 1" Heat Absorbing Glass *Fabrics Installed Internally, Zero-Degree Profile Angle *Solar Heat Gain Coefficient (SHGC) shown calculated according to Office of Building Technology, State and Community Programs, Energy Efficiency and Renewable Energy, U.S. Department of Energy’s definition of SHGC. SHGC represents the percentage of solar heat gain that is transmitted to the interior through the glass and shading system. If you are using glass whose performance is listed in terms of SC, you may convert to SHGC by multiplying the SC by 0.87.

More Information

Print

ShareIt

GreenGuard

SheerWeave Style 7000
V39 Graphite

Style 7000 is uniquely designed to provide total light blockage when complete room darkening is needed. With a broad range of decorator colors, the look and feel of rich cloth and a PVC-free composition, Style 7000 will enhance the beauty and function of both commercial and residential spaces.

Specifications
Fire Classification
California U.S. Title 19 (small scale), NFPA 701-2004 TM#1 (small scale), BS 5867 2008 Part 2 Type B Performance, CAN/ULC-S 109-03 (large and small scale), ASTM E 84 (Class 1), and CAN/CGSB2-4.162-M80
Bacteria and Fungal Resistance
ASTM G21-96, AATCC 174-1998 Part II and III
Environmental Certification
Certified to GREENGUARD and GREENGUARD Gold standards for low chemical emissions into indoor air during product usage
Lead Free
RoHS/Directive 2002/95/EC, US Consumer Product Safety Commission Section 101 and ANSI/WCMA A 100.1-2007 for lead content
Standard Uses
Roll-up shade
Warranty
5-year interior

Technical Data

Standard Widths 94" and 118" (238.8cm and 299.7cm)
Standard Roll Length 30 Linear yards (27.4m)
Composition 100% Polyester with Acrylic Foamed Backing (PVC-free)
Mesh Weight 13.41 oz/yd2 (454.67 g/m2)
Fabric Thickness .026 in (0.66mm)
Openness Factor Opaque
Acoustical Value NRC 0.10 / SAA 0.08
Acoustical Performance NRC (Noise Reduction Coefficient) and SAA (Sound Absorption Average) tested in accordance with ASTM C423-09a.
SheerWeave Style 7000 Solar Optical Properties SHGC/G Value g-tot (glass & blind)
Single Insulating
Solar
Transmittance
Solar
Reflectance
Solar
Absorption
Visual
Transmittance
1/8CL 1/4CL 1/4HA 1CL 1HA
7000 P62 White 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 P64 Sand 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 P63 Birch 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 Q57 Wheat 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 Q58 Mushroom 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 U67 Canvas 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 U69 Cocoa 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 V41 Canyon 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 V39 Graphite 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 V40 Onyx 0 64 36 0 0.27 0.27 0.26 0.26 0.21

*TS - Solar Transmittance, RS - Solar Reflectance, AS - Solar Absorption, TV - Visual Transmittance *SHGC = Solar Heat Gain Coefficient *1/4 CL = 1/4" Clear Glass, 1 HA = 1" Heat Absorbing Glass *Fabrics Installed Internally, Zero-Degree Profile Angle *Solar Heat Gain Coefficient (SHGC) shown calculated according to Office of Building Technology, State and Community Programs, Energy Efficiency and Renewable Energy, U.S. Department of Energy’s definition of SHGC. SHGC represents the percentage of solar heat gain that is transmitted to the interior through the glass and shading system. If you are using glass whose performance is listed in terms of SC, you may convert to SHGC by multiplying the SC by 0.87.

More Information

Print

ShareIt

GreenGuard

SheerWeave Style 7000
V40 Onyx

Style 7000 is uniquely designed to provide total light blockage when complete room darkening is needed. With a broad range of decorator colors, the look and feel of rich cloth and a PVC-free composition, Style 7000 will enhance the beauty and function of both commercial and residential spaces.

Specifications
Fire Classification
California U.S. Title 19 (small scale), NFPA 701-2004 TM#1 (small scale), BS 5867 2008 Part 2 Type B Performance, CAN/ULC-S 109-03 (large and small scale), ASTM E 84 (Class 1), and CAN/CGSB2-4.162-M80
Bacteria and Fungal Resistance
ASTM G21-96, AATCC 174-1998 Part II and III
Environmental Certification
Certified to GREENGUARD and GREENGUARD Gold standards for low chemical emissions into indoor air during product usage
Lead Free
RoHS/Directive 2002/95/EC, US Consumer Product Safety Commission Section 101 and ANSI/WCMA A 100.1-2007 for lead content
Standard Uses
Roll-up shade
Warranty
5-year interior

Technical Data

Standard Widths 94" and 118" (238.8cm and 299.7cm)
Standard Roll Length 30 Linear yards (27.4m)
Composition 100% Polyester with Acrylic Foamed Backing (PVC-free)
Mesh Weight 13.41 oz/yd2 (454.67 g/m2)
Fabric Thickness .026 in (0.66mm)
Openness Factor Opaque
Acoustical Value NRC 0.10 / SAA 0.08
Acoustical Performance NRC (Noise Reduction Coefficient) and SAA (Sound Absorption Average) tested in accordance with ASTM C423-09a.
SheerWeave Style 7000 Solar Optical Properties SHGC/G Value g-tot (glass & blind)
Single Insulating
Solar
Transmittance
Solar
Reflectance
Solar
Absorption
Visual
Transmittance
1/8CL 1/4CL 1/4HA 1CL 1HA
7000 P62 White 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 P64 Sand 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 P63 Birch 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 Q57 Wheat 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 Q58 Mushroom 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 U67 Canvas 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 U69 Cocoa 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 V41 Canyon 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 V39 Graphite 0 64 36 0 0.27 0.27 0.26 0.26 0.21
7000 V40 Onyx 0 64 36 0 0.27 0.27 0.26 0.26 0.21

*TS - Solar Transmittance, RS - Solar Reflectance, AS - Solar Absorption, TV - Visual Transmittance *SHGC = Solar Heat Gain Coefficient *1/4 CL = 1/4" Clear Glass, 1 HA = 1" Heat Absorbing Glass *Fabrics Installed Internally, Zero-Degree Profile Angle *Solar Heat Gain Coefficient (SHGC) shown calculated according to Office of Building Technology, State and Community Programs, Energy Efficiency and Renewable Energy, U.S. Department of Energy’s definition of SHGC. SHGC represents the percentage of solar heat gain that is transmitted to the interior through the glass and shading system. If you are using glass whose performance is listed in terms of SC, you may convert to SHGC by multiplying the SC by 0.87.